Touchscreen thermostat Settings | Using the function menu

Header Image

Touchscreen thermostat | Using the function menu

The function menu allows you to enable / disable features, calibrate sensors and change modes, please see the chart below.

Function Number Function Description Function Values
1 Select the operation mode of either Air and floor, Air only or floor only (Default is air and floor) 1 = Air and Floor
2 = Air only
3 = Floor only
2 Room sensor selection, the thermostat has an inbuilt sensor but can use an external wired sensor on P2 of the wiring diagram (wired sensor not supplied) 1 = Inbuilt Sensor
2 = Wired Sensor
3 Calibrate the room temperature, this setting is used to ensure the displayed temperature is correct. You will need a thermometer to measure accurate temperature. Use arrow up and down to set the correct temperature.
4 Calibrate the floor temperature, this setting is used to ensure the displayed floor temperature is correct. You will need a thermometer to measure accurate temperature. Use arrow up and down to set the correct temperature.
5 Set the floor temperature limit, this is used in air and floor mode to limit the floor temperature, the default is 28 Degrees C Use arrow up and down to set the correct temperature.
6 Set the frost mode temperature, if set to frost mode the underfloor heating will only activate if the temperature falls below the set value, Default is 5 Degrees C Use arrow up and down to set the correct temperature.
7 Switching differential, the switching differential is the amount of degrees between setpoint and heating reactivation. 1 = 1 Degree (default)
2 = 2 Degree
3 = 3 Degree
8 Consumption information, 7 day log of time the underfloor is active, this is used to work out consumption. use arrows to scroll through the days.
9 Display temperature function, Allows you to toggle between degrees C / Degrees F Use arrow up and down to toggle between C / F
10 Number of daily set points, allows you to toggle between 2 or 4 setpoints Use the arrows up and down to toggle between 2 and 4 default is 4
11 Toggle the screen backlight, as default the back light is set to be on when the thermostat is being used. 01 = Backlight enabled
00 = Backlight disabled
12 Toggle the keypad beep, this function is enabled by default 01 = Keypad beep enabled
00 = Keypad beep disabled

Click here for details of how to use the functions.